Strona 1 - INTERCOM SYSTEM

TOA EX-16INTERCOM SYSTEMINSTALLATION HAND BOOKTOA ELECTRIC CO., LTD.KOBE, JAPAN

Strona 2

Station SpecificationsPermissible LoopResistance:Input/Output Impedance:Loudspeaker Output:Handset Speaker Output:300 ohms600 ohms (balanced)300mW max

Strona 3 - 2.1 Exchange

1. Power Switch2. Power Indicator3. Output Volume Control4. Input Volume Control5. Rubber Foot6. AC Inlet7. Voltage Selector8. 8-Pin Terminal Board9.

Strona 4 - Crosstalk:

3. Installation of the EX-16 System3.1 Precautions for Installation3.1.1 ExchangePay particular attention to the following points:* The layout should

Strona 5 - EX-16 DIMENSIONS

3.1.2 StationsParticular attention should be given to the following points duringinstallation.* A desk-type, wall-mounting-type or desk/wall-type sh

Strona 6 - control

3.2 Cable InstallationWire type, number of wire pairs and number of individual wires are to bedetermined for individual sections of the wiring system

Strona 7

3.4 WiringGeneral Information* Wiring should be done independent of public telephone lines.* The wiring conduit is often installed underground or em

Strona 8 - 2.1.4 System Block Diagram

3.5 Piping* Where wiring is to be passed through a wall or the like, it should beprotected by a hard PVC or metal tube.* If the number of connecting

Strona 9 - 2.2 Stations

3.6 Connection between the station and the exchange4-Pin Jack (YC-101)(YC-103: 4-Pin Jack for flush-mount)NOTE: Use 4" X 2" Switch Box for

Strona 10 - 2.3. Accessories

Note:Connect the individual cables inorder, starting with the top ter-minal.When using the clipping tool, besure that the cutting edge is on theside

Strona 11 - Voice Switch or Press-To-Talk

EX-16 WIRING INSTRUCTIONS1 STATION CONNECTIONSor2 TALK-BACK CONNECTIONSTKU-11 TERMINALTERMINAL BOARDSPEAKER LINE INPUT17

Strona 12

1. Introduction ...2. Introduction of the EX-16 S ystem...2.1 Exchange.

Strona 13 - 3.1.3 TKU-11

3.7 AC/DC Power Supply ConnectionA 5P terminal for AC and DC power supply is provided on the DSM-16.The power cable, YA-308 or YA-309, can be connecte

Strona 14 - 3.2 Cable Installation

3.8.1 BGM InputInput impedance: 50 K (unbalanced)Input level: -10dB max.Output level: 100mW(a) Remove the short bar connected to the terminal.(When

Strona 15 - 3.4 Wiring

3.8.4 Wiring DiagramBGMAMPDOOR20

Strona 16 - 3.5 Piping

3.9 Connection of the Talk-Back UnitConnection of the talk-back unit is shown below.SPEAKERSPEAKEREX-16TERMINALBOARDWhen the talk-back speaker is used

Strona 17 - (not Polarity Specified)

3.10 Connection of the Speaker StationIn the EX-16, instead of using a station, a speaker for one-way conversationcan be installed using a jumper

Strona 18 - Push down

3.10.3 Connection with the ExchangeConnect speakers to terminals 1 and 2 as shown in the diagram. (Leaveterminals 3 and 4 open.)3.10.4 On/Off Control

Strona 19

Jumper for Speaker Station SelectionJumper for BGM On/OffFor BGM on/off operation remotely, thecontrol line can be extended the same wayas for station

Strona 20 - Power Supply Cables

4. Installation Adjustment4.1 Inspect Before Turning Power On.* Before supply power, check the power connections (power connectionsshould be complet

Strona 21 - Contact capacity: 125VA

Program Switch DetailsPower RemoteDoor Remote1. Set the mini-jump in the JP1 position for door remote. Relay goes on for4 seconds when buttons and

Strona 22 - 3.8.4 Wiring Diagram

4.3.1 Precedure(1) Turn on power switch on the exchange.(2) Adjust the sound level of the external PA paging and check the powerremote function.(a) Co

Strona 23 - TERMINAL

1. IntroductionThis is the installation manual for the exchange, stations and othercomponents of TOA Intercom System EX-16. It includes an outline of

Strona 24 - To exchange

(3) If the voltage measured is normal at every point, connect one unitat a time checking the voltage after each connection.(4) If the voltage is upse

Strona 25 - 3.10.4 On/Off Control of BGM

4.3.3 Relationship Between Ambient Noise and Conversation ModeThe EX-16 system is provided with voice switches for the press-to-talkfunction which is

Strona 26 - Jumper for BGM On/Off

5.1 Fault in Exchange* When the power supply unit or the CPU-16 is out of order, the same kindof fault will occur at all stations.* When the LAU-16

Strona 27 - CPU-16 P.C.B

5.2 Fault in Specific Station OnlyFind the cause according to the following table if the fault lies with a specificstation only, not with all stations

Strona 28 - Power Remote

5.3 Fault in Cable1. One of transmitting lines (T-Line) is disconnectedSymptom:1-1 A can dial.1-2 A can hear B.1-3 B can not hear A.1-4 Noise is heard

Strona 29 - 4.3.2 Adjusting Method

3. T-Line and R-Line are shorted or mixed up.Shorted or mixed up3-1 A can not dial.3-2 Conversation is impossible betweenstations.3-3 When B dials A,

Strona 30

TOA ELECTRIC CO., LTD.KOBE, JAPANPrinted in Japan

Strona 31 - 5. Trouble Shooting Guide

2.1.2 SpecificationsThe exchange is available with the following specifications.EX-16 Capacity:Dimensions:Weight:16 lines max. (with paging function)

Strona 32 - 5.1 Fault in Exchange

(a) Structure of Exchange and Names of PartsLine Amp Unit (LAU-16)Central Processing Unit (CPU-16)ConnectorEX-16 DIMENSIONS in mmShort BarPower Transf

Strona 33

(b) CPU (Central Processing Unit)The Central Processing Unit is divided into two sections: common controland speech path.Common control: This section

Strona 34

(c) LAU (Line Amplifier Unit)The Line Amplifier Unit consists of a power supply circuit for stations,transmitting and receiving circuits for voice si

Strona 35

StationTerminalLAU-16(1)LAU-16(2)LAU-16(3)LAU-16(4)DSM-16Inside ViewUnits(e) Integral Terminal for Connecting StationsThe connection terminal for the

Strona 36 - Printed in Japan

2.2 Stations2.2.1 FeaturesThe stations used in the Toa Intercom EX-16 have the following features:1. Each station is provided with a male 4-pin plug (