Central Processing Unit for Tie-line System
EXES-6000
CP-63
For
INTERCOM SYSTEM
TOA EXES-6OOO INTERCOM SYSTEM
CP-63
INSTALLATION HAND BOOK
TOA ELECTRIC CO., LTD.
KOBE, JAPAN
133-21-081-1
Przeglądanie stron 0
1 2 3 4 5 6 ... 58 59

Podsumowanie treści

Strona 1 - INSTALLATION HAND BOOK

Central Processing Unit for Tie-line SystemEXES-6000CP-63ForINTERCOM SYSTEMTOA EXES-6OOO INTERCOM SYSTEMCP-63INSTALLATION HAND BOOKTOA ELECTRIC C

Strona 2 - CONTENTS

4. The Example of connection of EX-620 exchangeYR-801 must be connected to J15 for EX-620 exchange (for 128 stations), or to J7for EX-610 exch

Strona 3

5. The Example of connection of EX-620 exchangeYR-810 must be connected to J15 for EX-620 exchange (for 128 stations), or to J7for EX-610 exchan

Strona 4 - Unit Model

PART 1. OPERATING OF CP UNIT AND NO. 200 PROGRAMMING1. PRECAUTIONS FOR INSTALLATION OF CP-63Please read following instructions carefully to en

Strona 5 - Exchange Frame FR-610

Make sure that you have turned off the AC power switch.Connect the exchange, terminal boards and stations.Are Data Transmitting and Receiving Units

Strona 6

3. TROUBLE SHOOTING3-1 Check of ROM & NMOS-RAM - No calls on the system.1. Put the 4 "LINK SELECT" switches of the HC

Strona 7

3-6 The order of Tie-line link usageThe Tie-line Link Number which is used in calls between exchangesis not directly indicated, but you

Strona 8 - Exchange "A"

Reference for Connection Link Number between DL and Tl LinkDLLink NoExchange which callsTl Tie-line Link Number2 Tie-lines3 Tie-linesExchange

Strona 9 - 3. DIP Switch selection

4. CP-63 DIP SWITCHES FOR FUNCTION SELECTIONFunctionsLink Selection; Link No. 0 ~ 3Link Selection; Link No. 4 ~ 7Link Selection; Link No. 8 ~ 1 1Li

Strona 10

5. DIP SWITCH SELECTION AND STATION NO. 200 PROGRAMMINGFOR EACH FUNCTIONNo. 200 Programming should be proceeded in the following manner

Strona 11

6. FUNCTION CODE TABLE FOR STATION NO. 200 PROGRAMMINGA. Clearance at one timeFunctionGroupSABCDE*FunctionNumbering schedulesof Tie-line sy

Strona 12

CONTENTSINTRODUCTION TO THE INSTALLATION MANUAL FOR EXES-6000FUNCTIONS WHICH REQUIRE ADDITIONAL UNITSTIE-LINE CONNECTION OF THE EXCHANGE

Strona 13

FUNCTION CODE TABLE FOR STATION NO. 200 PROGRAMMINGB. Programming of SystemThe first station number of each exchange inorder of the exchang

Strona 14 - 3. TROUBLE SHOOTING

FUNCTION CODE TABLE FOR STATION NO. 200 PROGRAMMINGC. Programming of each FunctionFunctionFunc-tionCode1st Parameter2nd Parameter3rd Paramet

Strona 15 - 1. Tie-line for 2 exchanges

7. STATION NO. 200 PROGRAMMING FOR EACH FUNCTION7-1 EXECUTIVE PRIORITY (FUNCTION CODE 50)(HIGHEST PRIORITY)EXECUTIVE PRIORITY (HIGHEST PRIORITY

Strona 16

7-2 CONTINUOUS CALLING TONE (FUNCTION CODE 51)CONTINUOUS CALLING TONESTEP 1TouchFunction CodeNONew Registration?YESContinuously Called Station No.

Strona 17 - No.200 (20)~

7-3 STATIONS ALLOWED ACCESS TO ALL CALL (FUNCTION CODE 52)STATIONS ALLOWED ACCESS TO ALL CALLSTEP 1TouchFunction CodeNew Registration?NOYESAllowed S

Strona 18

7-4 STATIONS ALLOWED ACCESS TO CONFERENCE (FUNCTION CODE 53)STATIONS ALLOWED ACCESS TO CONFERENCESTEP 1TouchFunction CodeNew Registration?NOAllowed S

Strona 19 - A. Clearance at one time

7-5 AUTOMATIC ACCESS TO PAGING (FUNCTION CODE 54)HANDSET SUBSTATIONS ALLOWED ACCESS TO PAGINGSTEP 1TouchFunction CodeNew Registration?NOONTouchAllow

Strona 20

COMPLEMENTARY NOTES(1) Automatic Access to PagingThis function facilitates Paging / Paging response from aSubstation TL-600S. Just pickin

Strona 21

7-6 STATIONS ALLOWED ACCESS TO ONE-SHOT MAKE OUTPUT (FUNCTION CODE 56)STATION ALLOWED ACCESS TO ONE SHOT MAKE OUTPUTSTEP 1TouchFunction CodeNew Regis

Strona 22 - (HIGHEST PRIORITY)

7-7 STATIONS ALLOWED ACCESS TO MAKE/BREAK OUTPUT (FUNCTION CODE 57)STATIONS ALLOWED ACCESS TO MAKE/BREAK OUTPUTSTEP 1TouchFunction CodeNew Registratio

Strona 23 - Confirmation tone

INTRODUCTION TO THE INSTALLATION MANUAL FOR EXES-6000This manual forms part of the Installation Manual for TOA INTER-COM SYSTEM EXES-600

Strona 24

7-8 STATIONS ALLOWED ACCESS TO 8 SELECTABLE OR DECIMAL OUTPUT(FUNCTION CODE 58)STATIONS ALLOWED ACCESS TO 8 SELECTABLEOR DECIMAL OUTPUTSTEP 1TouchFunc

Strona 25 - New Registration?

7-9 STATIONS ALLOWED ACCESS TO 4 DECIMAL DIGITS OUTPUT (FUNCTION CODE 59)STATIONS ALLOWED ACCESS TO 4 DECIMAL DIGITS OUTPUTSTEP 1TouchFunction Co

Strona 26 - (Confirmation tone

7-10 SECRETARY TRANSFER (FUNCTION CODE 60)SECRETARY TRANSFERStep 1TouchFunction CodeNew Registration?NOExecutive Station No. Secretary Station N

Strona 27 - (5) Call by Dialing

7-11 MASTER/SUB RELATIONSHIP (FUNCTION CODE 61)MASTER/SUB RELATIONSHIPStep 1TouchFunction CodeNew Registration?NOYESSub Station No.TouchMaster St

Strona 28 - New Registration finished?

7-12 GROUP HUNTING (FUNCTION CODE 62)TRANSFERED STATION No. FOR GROUP HUNTINGStep 1TouchFunction CodeNew Registration?NOTouchOriginal Station No.Tra

Strona 29 - Be sure to depress the

7-13 PAGING ZONE (FUNCTION CODE 70)ESTABLISHMENT OF EACH PAGING ZONEStep 1TouchFunction CodeTouchPaging Zone No.(00~21, 00~45)1st Station No.of t

Strona 30 - (FUNCTION CODE 58)

GROUP BLOCKING 1ESTABLISHMENT OF EACH GROUPStep 1TouchFunction CodeGroup No.(1 ~6)Touch1st Station No.of the GroupLast Station No.of the GroupT

Strona 31 - Allowed Station No. OFF

7-15 CALLING PARTY INDICATION (LAMP TYPE) (FUNCTION CODE 72)Registration of station number(s) having indication panel.ESTABLISHMENT OF EACH GRO

Strona 32

7-16 GROUP BLOCKING 2 : ALLOWING CALLS AMONG GROUPS (FUNCTION CODE 81)GROUP BLOCKING 2ALLOWING CALLS AMONG GROUPSStep 1TouchFunction CodeNONew Regist

Strona 33 - Master Station No

7-17 GROUP BLOCKING 3 : ALLOWING GROUP ACCESS TO PAGING (FUNCTION CODE 82)GROUP BLOCKING 3ALLOWING ACCESS TO PAGING ZONESStep 1TouchFunction CodeNONew

Strona 34 - Original Station No

FUNCTIONS WHICH REQUIRE ADDITIONAL UNITSThose functions of the CP-63 which require either the addition of specific units or processing in ex

Strona 35

7-18 PROGRAMMABLE STATION NUMBERING (FUNCTION CODE 90)A. Programming of Single Station NumberPROGRAMMABLE STATION NUMBERINGStep 1TouchFunction CodeN

Strona 36 - GROUP BLOCKING 1

B. Programming of Serial Station NumbersPROGRAMMABLE STATION NUMBERINGStep 1TouchFunction CodeNONew Registration?YESFirst Last First LastHardwire

Strona 37 - Last Station No

8. PROGRAMMING DATA TABLEINITIAL PROGRAMMINGNote. (Mark *)The first station of each exchange becomes the Programming Station:Exchange "A"

Strona 38 - GROUP BLOCKING 2

< PROGRAMMING DATA TABLE 1 >Function Table for the SystemFunctionGroupSFunctionNumbering schedulesof tie-line systemSelection ofCalling Tone

Strona 39 - GROUP BLOCKING 3

< PROGRAMMING DATA TABLE 2>Function Table for Stations (1)Function GroupFunctionFunction CodeHardwiredStation No.Type of ExchangeExecutiv

Strona 40

<PROGRAMMING DATA TABLE 3>Function Table for Stations (2)Function GroupFunctionFunction CodeHardwiredStation No.Type of ExchangeExecutive Pr

Strona 41

<PROGRAMMING DATA TABLE 4>Function Table for Stations (3)Function GroupFunctionFunction CodeHardwiredStation No.Type of ExchangeExecutive

Strona 42 - INITIAL PROGRAMMING

Group Blocking among GroupsCallingGroup No.Called Group No.Others<PROGRAMMING DATA TABLE 5>Paging Zone TablePaging ZoneDepartmentA01020304050

Strona 43 - Function Table for the System

<PROGRAMMING DATA TABLE 7>Function Code 82Paging ZoneDepartmentAll CallIndividual Paging ZonesNo.000102030405060708091011121314158 (16 )9(1

Strona 44

Summary Table ofGroup Blocking (Function Code 71, 81, 82) andPaging Zone (Function Code 70)Note.indicates that registration is not necessary,

Strona 45

Example of Exchange Mounted on Intercom Cabinet Rack(For Tie-line System Including All-Call Paging and 7 Individual Zone Paging unit and one Da

Strona 46

PART 2. FUNCTION SELECTION FOR DATATRANSMITTING AND RECEIVING UNITS9. SETTING OF CHANNEL SELECT SWITCH OF TRANSMITTING UNIT (DT-E11)AND WOR

Strona 47 - (Lamp Type)

10. DIP SWITCH TABLE FOR DATA TRANSMITTING AND RECEIVING UNITSCHANNEL SELECT SwitchWORD SELECT Switch— 50 —

Strona 48 - Paging Group No

YR-802orYR-806YR-803Tie-line Unit TI-62<Terminal Board>YR-810Stations<Data Receiver(Equipment using DR-B61)>(Exchange A)<Data Tr

Strona 49 - Summary Table of

12. EXPLANATION OF DATA TRANSMITTING UNIT OUTPUT CHANNELSCHANNEL SELECTIONFUNCTIONSIN/OUT Annunciation(1 ) One-shot Make Output(50 contacts)(2)

Strona 50

13. EXPLANATION OF DATA RECEIVING UNIT OUTPUT DATA13-1 Channel 0 (CH. 0) In/Out AnnunciationCHANNEL SELECT SwitchEach Relay Output showslast

Strona 51 - WORD SELECT Switch

13-2 Channel 1 (CH. 1)(1) One-shot Make Output (50 contacts)(3) 8-Selectable Make Output (9 units)(5) 4 Decimal Digits Output (9 units)(2) M

Strona 52 - Tie-line Unit TI-62

13-3 Channel 2 (CH. 2) Calling Party Indication (Lamp Type) (1)Each "Calling Station" or "Waiting Station" is shown by Each

Strona 53

13-4 Channel 3 (CH. 3) Calling Party Indication (Lamp Type) (2)Each "Calling Station" or "Waiting Station" is shown by Ea

Strona 54 - (Relay Break)

Appendix. Instructions for building the CP-63 in the EXES-50001. The CPU-55/56 differ from the CP-62/63 in dial operation.FunctionContinuous Cal

Strona 55 - CHANNEL SELECT Switch

TOA ELECTRIC CO, LTD.KOBE, JAPAN

Strona 56

TIE-LINE CONNECTION OF THE EXCHANGES1. Function of the Central Processing Unit CP-63To make communications between exchanges possible in the

Strona 57

3. Numbering schedule for stations and paging zonesA. With personal number (Standard)B. Without personal numberZone No. 16 through 2

Strona 58 - X: 1 ~ 9, Y: 0~ 7

6. The relationship between the PI unit and the LM unit<The case where the tie-line system consisting of 2 or 3 exchangeshas an excha

Strona 59 - TOA ELECTRIC CO, LTD

WIRING FOR TIE-LINE CONNECTION OF THE EXCHANGESEach exchange can be connected by means of a cable with a diameter of 0.65mm (25.6 mils.)